D1X2B Mechanical Fiber Optic Switch


D1X2B Mechanical Fiber Optic Switch

  • Description
  • Releated Products
Mechanical Optical Switch is based on Advanced Optoelectronic Integrated Technology, it connects optical channels by redirecting an incoming optical signal into a selected output fiber. This is achieved using a Opto-Mechanical proprietary configuration and activated via an electrical control signal. With the development of optical communication, Optical Switch device is the key to a new generation of all-optical network in near future.

SYOPTEK designs and manufactures the most affordable high performance Mechanical Optical Switch. By state of art technologies, SYOPTEK optical switch is not affected by the polarization and wavelength, it offers ultra-high reliability, fast switching speed, low insertion loss, and bi-directional performance. Our optical switch products support, improve overall system cost to meet global demand of large bandwidth network.

Features
-Fast switching speed
-Unmatched Low Cost
-Low lnsertion Loss & PDL
-Latching or Non-Latching
-High Channel lsolation
-High stability and reliability

Applications
-Protection/Redundancy of fiber network
-Re-configurable Optical Add/Drop Multiplexing
-Optical Cross Connect (OXC)
-Channel Selectors
-Optical Spectral Monitoring (OSM)
-Optical Test Equipments
-Self station monitoring
-Epoxy-Free Optical Path

Performance:

Model

D1*2B

Operating wavelength

nm

850±40/1300±40

1260~1620

wavelength

nm

850&1300

1310&1550

Insertion loss

dB

Typ:1.0 Max:1.5

Return loss

dB

MM≥30 SM≥50

Cross talk

dB

MM≥35 SM≥55

PDL

dB

≤0.05

WDL

dB

≤0.25

TDL

dB

≤0.25

Repeatability

dB

≤±0.02

Voltage

v

3.0 or 5.0±0.5

Operating life

Time

≥107

Switch time

ms

≤8

Power handling

mW

≤500

Operating temperature

-20~+70

Storage temperature

-40~+85

Fiber color

P1、P1’:Blue P2、P2’:Red P3、P3’:White

Size

mm

27.0×12×8.2±0.2

Note: 1. Within operating temperature and SOP. 2. Excluding Connectors.

Pin Definition:

Type

State

Pin definition

Power

Condition monitoring

D1x2

1

5

6

10

2-3

3-4

7-8

8-9

Non-latching

A

P1-P2 P1’-P2’

--

--

--

--

Close

Open

Open

Close

B

P1-P3 P1’-P3’

V+

--

--

GND

Open

Close

Close

Open

Latching

A

P1-P3’ P2-P4’

--

--

GND

V+

Close

Open

Open

Close

B

P1-P1’ P2-P2’ P3-P3’ P4-P4’

V+

--

GND

--

Open

Close

Close

Open

Path Diagram:

Production Size:

Order Information:

XXXX—

XX—

XXXX

Wavelength

Operating Voltage

Fiber Type

Tube Type

Fiber Length

Connector

0850—850

1315—1310&1550

……

3L—3v, latching

5L—5v, latching

3N—3v, Non-latching

5N—5v, Non-latching

1—SM

2—MM 62.5/125

3—MM 50/125

1—250um

2—900um

00—Other

05—0.5m±5cm

10—1m±5cm

15—1.5m±5cm

20—2 m

……

0—Other

1—FC/PC

2—FC/APC

3—SC/PC

4—SC/APC

5—LC/PC

6—LC/APC